FC TECX and FCTEC SERIES
Fusible / Non-Fusible Combination Controls
 
Special Purpose Series - ECX Series Contactors | ECX Overloads
 
Special Purpose Series - HVAC - Pump
 
  • UL / CSA Manual Motor Disconnect with door safety interlocks. Industrial Controls Disconnects are load make, load break, UL Listed for motor load switching duty.
  • Fuse Blocks are type "J" as standard. For "R" Type, insert at end of part number "R" (same price), Type "CC" 30 Amp fuse block - Standard on FC TECX 18.
  • Type TECX & TEC Starter and overload relays are complete with precision ambient compensated heaters and differential single phasing protection.
 
Voltage
Design
Rating
UL
Fuse
Block
Amps
Catalog No.
Type FC TECX-
Fusible Disconnect Type Enclosed
Non Fusible #NFC TECX
Add "N" to part # for
Non Fusible
Omit Fuse Block Deduct:
(Metal)
General
Purpose
NEMA1
-M01
(Non-Metal
Dust Tight
Outdoor
NEMA4X
-4X
(Metal)
Dust Tight
Drip Tight
NEMA12/4
-M4
200/230
5
30CC
FC TECX-18-1*-**-
$510
$620
$620
$-26
460
10
30CC
FC TECX-18-2*-**-
$510
$620
$620
$-26
200/230
10
60
FC TECX-32-1*-**-
$545
$690
$690
$-26
460
20
60
FC TECX-32-2*-**-
$545
$690
$690
$-26
200/230
15
60
FC TECX-65-1*-**-
$700
$790
$790
$-26
460
30
60
FC TECX-65-3*-**-
$700
$790
$790
$-26
200/230
25
100
FC TECX-95-1*-**-
$850
$990
$990
$-26
460
50
100
FC TECX-95-2*-**-
$850
$990
$990
$-26
 
FCTEC - 40HP to 200HP
Voltage
Design
Rating
UL
Fuse
Block
Amps
Catalog No.
Type FC TEC-
Fusible Disconnect Type Enclosed
Non Fusible #NFC TEC
Add "N" to part # for
Non Fusible
Omit Fuse Block Deduct:
(Metal)
General
Purpose
NEMA1
-M01
(Non-Metal
Dust Tight
Outdoor
NEMA4X
-4X
(Metal)
Dust Tight
Drip Tight
NEMA12/4
-M4
200/230
40 / 60
100
FC TEC-150*-**-
$1170
$1430
$1430
$-52
460
100
200
FC TEC-150*-**-
$1170
$1430
$1430
$-52
200/230
50 / 60
200
FC TEC-185*-**-
$1390
$1650
$1650
$-52
460
125
200
FC TEC-185*-**-
$1390
$1650
$1650
$-52
200/230
75 / 100
400
FC TEC-330*-**-
$2150
$2660
$2660
$-88
460
200
400
FC TEC-330*-**-
$2150
$2660
$2660
$-88
 
Step 1: Size - Choose from the UL HP and Voltage list per your application.
Example: 5HP 230V 3 Phase Part Number - FC TECX18-1*
Step 2: Coil * - From the coil suffix chart below select the appropriate coil suffix.
Example: 120VAC Coil = A - Part #FC TECX18-1A-
Step 3: Overload Amps ** - This step requires a suffix for your overload protection, refer to "Overload Relay Suffix Table" below.
Example: 5HP @ 230V 3 Phase, if 13 Full Load Amps = Suffix "13A"
Step 4: Enclosure - Specify "Open" or "Enclosed" requirments.
Example: If NEMA 12 Complete Part # FC TECX18-1A-13A-M4
 
* - Add Suffix to Part Number
AC Voltage
-A
120V
-C

208 / 230V

-E
480V
-F
600V
-D
380V
-G
24V
-H
280V
** - Add Suffix to Part Number
Overload Amp Range
-.63A
.4 to .63A
-1A
.63 to 1A
-1.6A
1 to 1.6A
-2A
1.25 to 2A
-2.5A
1.6 to 2.5A
-4A
2.5 to 4A
-6A
4 to 6A
-8A
5.5 to 8A
-10A
7 to 10A
-13A
9 to 13A
-18A
12 to 18A
-25A
17 to 25A
-32A
23 to 32A
-36A
28 to 36A
-40A
30 to 40A
-50A
37 to 50A
-65A
48 to 65A
-80A
63 to 80A
-93A
80 to 93A

Please contact Cal-Centron for additional Information.