BD5934
Safemaster / Safety Module (datasheet - pdf 194kb)
Please note: Contact Cal-Centron for current pricing.
- 1, 2 or 3 N.O. safety contacts, 0 or
1 N.C. auxiliary contacts
- Emergency stop circuit, interlocks, rope pull and monitor
of safety gates and mats
- Single circuit protection
- Gold contact rated for 300ma @ 60V PLC input
- Satisfies EU directive for machines:
98/37/RG, EN 60 204-1, DIN VDE 0113-1
|
|
|
 |
BD5935 Safemaster / Safety Module (datasheet - pdf 196kb)
- 1 or 3 N.O. safety contacts, 1 N.C. auxiliary
contacts
- Emergency stop circuits, interlocks, rope pulls
and monitor of safety gates and mats
- 1 or 2 channel connections
- Gold contacts rated for 300ma @ 60V PLC input
- Removal terminal strips
- Over-voltage & short circuit protection
- Selectable cross fault detection in E-stop
- Power "ON" or manual activation
|
|
|
 |
BD5987 Safemaster / Safety Module (datasheet - pdf 201KB)
- 1 or 2 N.O. safety contacts, 0 or 1 N.C. auxiliary
contacts
- Emergency stop circuits, interlocks, rope
pulls and monitor of safety gates and mats
- 1 or 2 channel connections
- Gold contacts rated for 300ma @ 60V PLC input
- Over voltage & short circuit protection
|
|
|
|
|
 |
BG5925 Safemaster / Safety Module (datasheet - pdf 208kb)
- 1, 2 or 3 N.O. safety contacts, 0 or 1 N.C.
auxiliary contacts
- Emergency stop circuit, interlocks, rope pull
and monitor of safety gates and mats
- Single and two channel operation
- Removable terminal strips, Manual / Auto restart
- Selectable with or without cross fault monitoring
in the E-stop loop
- Satisfies EU directive for machines:
98/37/RG, IEC 204-1, DIN VDE 0113-1, EN 954-1
|
|
|
 |
BH5928 Safemaster / Emergency Stop Module (datasheet - pdf 226kb)
- 3 N.O. or 2 N.C., 1 N.C. not delay, 3 N.O delay
- Emergency stop safety gate monitoring stop
category 1 can be achieved
- 1 & 2 channel operation with or without cross
fault monitoring
- Removable terminal strips
- Gold plate contacts, rated @ 300ma @ 60V PLC
input
- Address EU directive for machines 98/37/EG
and per EN 60 204-1, Address EU directive for machines 98/37/EG
and per EN 60 204-1, DIN VDE 0113-1, 241-457
|
|
|
 |
BL5931 Safemaster / Safety Module (datasheet - pdf 231kb)
- 5, 6 or 7 N.O. safety contacts, 1 or 4 N.C.
auxiliary contacts
- Emergency stop circuits, interlocks, rope pulls
and monitor of safety gates and mats
- Line fault detection at the on-pushbutton
- Optional cross fault detection in the emergency
stop circuit
- Removable terminals
- Feed back circuit for monitoring external contactors
|
|
|
 |
BN5983 Safemaster / Safety Module with Time Delay (datasheet
- pdf 213kb)
- 3 N.O. safety contacts, 1 N.O. auxiliary contacts,
1 N.O. time delay
- Emergency stop circuits, interlocks, rope pulls
and monitor of safety gates and mats
- Channel 1 or 2 connection
- Feedback circuit for external contact monitoring
- Removable terminal strips
- Over-voltage and short circuit protection
- Achieves EC directive for machine 98/37/EG
and EN 60204-1, DIN VDE 0113-1
|
|
|
 |
BO5988 Safemaster / Safety Module (datasheet - pdf 218kb)
- 3 or 6 N.O. safety contacts, 0 or 1 N.C. auxiliary
contacts, 1 N.C. time delay
- Emergency stop circuits, interlocks, rope pulls
and monitor of safety gates and mats
- 1 or 2 channel connections
- Optional auto or manual actuation
- Feedback inputs for external contactor monitoring
- Short circuit & over-voltage protection
- Gold plated contacts rated 300ma @ 60V PLC
- Achieves EC directive for machines 98/37/EG
and EN 60204-1,
DIN VDE 0113-1
|
|
|
 |
BD5985N Safemaster / Safety Gate Monitor (datasheet - pdf 194kb)
- 2 N.O. safety contacts
- Emergency stop circuits, interlocks, rope pulls
and monitor of safety gates and mats
- Gold plated contacts rated
300ma @ 60V PLC
- Monitoring of external contactor with input
for feedback over-voltage & short circuit protection
- Achieves EC directive for
machines 98/37/EG and EN 60204-1,
DIN VDE 0113-1, 241-457
|
|
|
|
|
 |
BL5933 Safemaster / Safety Module (datasheet - pdf 188kb)
- 2, 3 N.O. safety contacts, 0, 1 N.C. auxiliary
contacts
- Two hands must be accounted for BEFORE and
during dangerous machine operation
- Press machines, metalworking
- Optional dual voltage available
- 2 push button inputs with 1 N.O., 1 N.C.
|
|
|
 |
BA7924 Safemaster / Delay Module (datasheet - pdf 195kb)
- 1 N.O. safety contact, 1 N.C. auxiliary contact
- Delay switch-off in safety oriented controls
(release safety gate once dangerous has ceased.)
- Used to achieve EU directive for machine 98/37/E,
DIN EN 61 812-1 and DIN EN 60 204-1
- Optional redundant timing circuit
- Fixed or adjustable up to 30 second time delay
98/37/RG, EN60 204-1, DIN VDE 0113-1
- Optional 1 or 2 timing circuit
|
|
|
 |
BN3081 Safemaster / Expansion Module (datasheet - pdf 177kb)
- 7 N.O. safety contacts, 1 N.C. auxiliary contact
- Used in creating additional contacts for emergency
stop modules and / or safety door monitor
- Used to achieve EC directive for machines 98/37/EG,
per IEC 204-1,
EN 60204-1 and DIN VDE 0113-1
- Redundant and positive guided contacts
- 1 or 2 channel connector
- Removable terminal strips
|
|
|
|
|
|