Safety Relays - Safety Modules
Relay Selection Guide

When correctly selected and interfaced, fitment of Dold Safety Relays will allow your control system to conform with the current safety standards required for CE certification. They are used and specified by many leading machinery manufacturers with Dold Industries.

Stopping by immediate removal of power to all actuators. This should be achieved by hard wired electromechanical components and its function shall not depend on software or electronic logic. This form of stopping is sufficient if removal of all power allows the machine to stop in a fast and safe manner.

Condition '1' Controlled Stop

This enables power to be maintained on the machine actuators that are essential to allow the machine to stop in a safe and fast manner, e.g. DC injection brakes, drive systems etc. After stopping is achieved, power must then be removed from all actuators via an electromechanical switching device. Dold safety relays are designed for use on risk applications 1-2-3-4 where conventional relays are not considered reliable. They provide the necessary redundancy, cross monitoring and self checking features mentioned in the EN Standards, and are suitable for single or dual channel installations.

Model
Contacts
Aux
Voltage
Case
Width
Reset
Risk
Category
N/O
N/C
Aux
Timed
Man
Auto
Emergency Stop Relays
BD5987.02
2
-
-
-
AC or DC
45
MON*
-
2 to 3
BD5987.03
2
1
-
-
AC or DC
45
MON*
-
2 to 3
BD5987.04
1
1
-
-
AC or DC
45
MON*
-
2 to 3
BG5925.03
3
-
-
-
24V DC or AC
22.5
MON*
Y
2 to 4
BG5925.22
2
1
-
-
24V DC or AC
22.5
MON*
Y
2 to 4
1
1
-
-
24V DC or AC
22.5
MON*
Y
2 to 4
BG5925.02
2
-
-
-
24VDC or AC
22.5
MON*
Y
2 to 4
BD5935.16
1
1
-
-
AC or DC
45
MON*
Y
2 to 4
BD5935.48
3
1
-
-
AC or DC
45
MON*
Y
2 to 4
BO5988.48
3
1
-
-
AC or DC
100
MON*
Y
2 to 4
BO5988.61
6
1
-
-
AC or DC
100
MON*
Y
2 to 4
BO5988.62
6
1
-
-
AC or DC
100
MON*
Y
2 to 4
Emergency Stop Relays with Safety Timer
BO5988.47
3
1
-
1
AC + DC
100
MON*
Y
2 to 4
BH5928.91
2
2
-
2
AC or DC
45
-
-
-
BH5928.92
2
1
-
3
AC or DC
45
-
-
-
BH5828.93
3
-
-
3
AC or DC
45
-
-
-
Emergency Stop Relays
BL5931.60
5
1
-
-
AC or DC
90
MON*
Y
2 to 4
BL5931.63
7
1
-
-
AC or DC
90
MON*
Y
2 to 4
BL5931.64
6
4
-
-
AC or DC
90
MON*
Y
2 to 4
BG5924.02
2
-
-
-
AC or DC
22.5
Y
Y
2
BD5934.02
2
-
-
-
AC or DC
45
Y
Y
2
BD5934.16
1
1
-
-
AC or DC
45
Y
Y
2
BD5934.48
3
1
-
-
AC or DC
45
y
y
2
Extension Modules
BN3081.63
7
1
-
-
AC or DC
100
Y
Y
2 to 4
Safety Timers
BA7924.21
-
1
-
1
AC or DC
45
-
-
2 to 3
BA7924.21/003
-
1
-
1
24VDC
45
-
-
2 to 4
Safety Gate Monitors
BD5985.02
1
1
-
-
AC or DC
45
-
-
2 to 3
Two Hand Safety Relays
BD5980.02
2
-
-
-
AC or DC
45
-
-
CAT 111A
BL5933.48
3
1
-
-
AC or DC
90
-
-
CAT 111C
BL5933.02
2
-
-
-
AC or DC
90
-
-
CAT 111C
BD5936.17
2
2
-
-
AC or DC
45
-
-
2 to 3
 

Please contact Cal-Centron for additional Information.